Welcome

CLEANERS
DOWNLOAD INFO SHEET
» All Wood Cleaner
» Concrete/Masonry Cleaner
» Mold-Eliminator
» Deck Restorer
» Re-new Concrete Rust &
» Stain remover
CONCRETE WATERPROOFERS
» Concrete / Masonry
» Marine Concrete / Masonry
» Industrial Multi-Surface
» Industrial Marine Multi-Surface
» Total Wood Protection
» Exotic Wood Protection
» Marine Wood Protection
» Composite Decking
» Industrial Multi-Surface
» Industrial Marine Multi-Surface
WHERE TO PURCHASE
» Retail Locations
» Retail Display Photos
» Locate A Distributor
TINTED FORMULAS
» View Tint Sample Photos
PRODUCT INFORMATION
» Testimonials
» Features & Benefits
» Beading vs. Sheeting
» Compare Labels!
» Seal-Once Concrete vs. Competitors
» Seal-Once Wood vs. Competitors
» FAQs
» NIC Cleaners Brochure
» Seal-Once Wood Brochure
» Seal-Once Concrete Brochure
» Download Product
» Information Pack PDF
TECHNICAL DATA
» Product Specs
» Toxicity / MSDS
» ASTM Test Results
» Test Results Summary
Made in the USA.
Manufactured & Distributed by New Image Coatings, LLC
Manchester, NH 03101
©2011 New Image Coatings, LLC

Seal-Once™ ASTM Test Results


Summary and Comments for ASTM Test Results
for Concrete

Seal-Once Clear Concrete/Masonry Formula was tested according to 3 ASTM methods for evaluation on concrete or concrete containing matrices:

1. ASTM F1869-98 (Standard test method for measuring moisture vapor emission of concrete sub floor using anhydrous calcium chloride)

SEAL-ONCE HAD A VAPOR EMISSION RATE (LB/1000PI2/24HRS) OF 3.9 AVERAGE WHILE UNTREATED REFERENCE CONCRETE BLOCKS AVERAGE 7.4. THIS MEANS THAT MOISTURE TRAPPED WITHIN CONCRETE OR OTHER SUBSTRATE WILL STILL ESCAPE AT A RATE 47% OF THAT OF RAW CONCRETE WHICH IS EXCELLENT.
2. ASTM C140-02 (Standard test methods for sampling and testing concrete masonry and related units-absorption and density)

UNTREATED CONCRETE MEGA-PAVE AND PERMACON PRODUCTS HAD A MOISTURE ABSORPTION RATE, ON AVERAGE BASED ON DENSITY, 2.9%. TREATED PRODUCTS WERE TESTED WITH SEAL-ONCE, ABSORPTION RATE OF 1.24%. THEREFORE, UNTREATED PRODUCTS ABSORBED 233% MORE MOISTURE THAN WHEN TREATED WITH SEAL-ONCE.
3. ASTM C672/C672M-98 (Standard test methods for scaling resistance of concrete surfaces exposed to de-icing chemicals)

CONCRETE IS COMPOSED OF SAND AND AGGREGATE WHICH ARE VERY HYDROPHILIC (WATER LOVING) HENCE ARE CAPABLE OF ABSORBING LARGE AMOUNTS OF WATER. THIS IS WHY THE FREEZE THAW TEST (ASTM C672) CAN BE SO DIFFICULT AS THE MOISTURE INGRESS INTO THE CONCRETE AND FREEZES IT INDUCES SCALING BECAUSE FREEZING WATER IS VERY STRONG. SEAL-ONCE HAD ZERO WEIGHT LOSS OR SCALING EVEN AFTER 50 FREEZE THAT CYCLES. THIS SHOWS THAT SEAL-ONCE CAN PROVIDE AN EXCELLENT LEVEL OF PROTECTION FOR CEMENTITOUS SUBSTRATES FOR MANY YEARS.


Summary and Comments for
ASTM Test Results for
Composite Decking

Seal-Once Composite Decking ASTM Test Method for Microbial Growth (mold & mildew)
1. ASTM D3274
Standard test method for evaluating degree of surface disfigurement of paint films by microbial (fungal or algal) growth or soil and dirt accumulation.
Passed 16 week test – no growth
2. ASTM D3273
Standard test method for resistance to growth of mold on the surface of interior coatings in an environmental chamber.
Passed 16 week test – no growth